A sudden increase in turbine generator vibration is a condition to assess against the machine’s operating limits, not a diagnosis by itself. Imbalance, alignment changes, bearing problems and rubbing can produce overlapping symptoms. The most useful initial distinction is whether the change is real, where it is strongest, and how it varies with speed, load and temperature.
When vibration exceeds an alarm or trip limit, rises rapidly, or coincides with abnormal bearing temperature, oil pressure or unusual noise, follow the site’s operating and shutdown procedures and the equipment manufacturer’s instructions. Do not bypass protective devices or continue operating solely to collect diagnostic data.
Compare the affected channel with its previous readings at similar speed, load and thermal conditions. Record the time of the change and any preceding event, such as a restart, maintenance intervention, load change or lubrication disturbance. A gradual increase over several weeks calls for a different investigation from a step change immediately after a shutdown.
Check whether the measurement is shaft-relative vibration from a proximity probe or casing vibration from a bearing housing sensor. These measurements describe different motion and should not be compared as though they were interchangeable. Also confirm the units, whether the value is peak, peak-to-peak or RMS, the frequency range and the sensor location.
A faulty probe, loose mounting, damaged cable or incorrect instrument configuration can imitate a machine problem. Compare redundant channels, where available, and check the instrument system using approved procedures. A stable reading on another channel does not automatically invalidate an alarm: a local fault can affect one bearing or direction more than another. Electrical checks and work near rotating equipment must follow site safety procedures.
Overall vibration is useful for protection and trending, but a frequency spectrum and phase data can make the investigation more discriminating. Capture data at the affected bearing and at adjacent turbine and generator bearings, using the same measurement settings where practical. A speed reference is needed for reliable phase and running-speed comparisons.
These signatures can coexist. For example, a rotor may show increased 1× vibration because a bearing condition has changed its dynamic response, even though the rotor’s physical balance has not changed. Correcting the apparent symptom without identifying that change can leave the underlying fault in place.
Plot vibration against speed during an authorized run-up or coast-down, if such data already exists or can be obtained safely under an approved procedure. A peak near a critical speed may be expected during passage through it, but its amplitude, phase change and decay should be compared with commissioning or previous run data. Do not dwell at a critical speed to investigate it unless the manufacturer’s procedure expressly permits the operation.
At constant speed, compare vibration at different loads and temperatures. A change that follows load may reflect thermal growth, steam conditions, generator forces or a support change rather than simple rotor imbalance. A change following warm-up or shutdown can also suggest thermal distortion or a clearance issue. Record the sequence: vibration rising before a temperature change may have a different implication from vibration rising after it.
Steam conditions deserve attention where vibration appears with a change in admission, extraction or exhaust conditions. For an Steam Turbine operating in an extraction or back-pressure arrangement, changes in process demand can alter thermal and mechanical loading. Compare valve positions, pressures and temperatures with the machine’s normal behavior before attributing the change to a rotor fault.
Review bearing metal temperatures, oil inlet pressure and temperature, oil flow indications and any recent filter or oil-system alarms. Compare readings across bearings and with the historical range for the same operating state. Oil contamination, restricted supply or an incorrect temperature can affect the oil film and bearing condition, but an oil alarm does not by itself establish the extent of bearing damage.
During a shutdown, inspect bearing components and clearances in accordance with the manufacturer’s instructions. Document wear patterns and retain relevant findings before cleaning or replacing parts. Check oil and filters for evidence of contamination using the site’s sampling and analysis procedures; particle findings need interpretation alongside bearing and oil-system observations.
Examine the support system as well as the rotating components. Loose hold-downs, damaged grout, foundation cracking or pipework imposing excessive forces can alter bearing alignment or stiffness. Compare housing vibration with shaft-relative readings: a large change in housing motion may direct attention toward the support, while shaft motion should be assessed in the context of bearing clearances and probe position. Neither measurement alone establishes the condition of the whole rotor train.
Do not schedule field balancing solely because vibration is high at 1× running speed. Before changing balance weights, verify the measurement, review phase stability and check for recent changes in alignment, bearings, rotor condition and operating conditions. Balancing a rotor affected by a temporary thermal bow or a loose support can mask the problem at one condition and make behavior worse at another. Balancing and coupling work should be performed only under approved procedures by qualified personnel.
For suspected misalignment, compare the as-found coupling measurements with the specified alignment targets, then investigate support, pipe strain and thermal-growth assumptions before resetting the alignment. For suspected looseness or bearing damage, inspection findings should guide repair scope; tightening accessible bolts without checking the condition of the joint or foundation may not restore the original support stiffness.
After corrective work, retain the as-found and as-left measurements, repair details and operating conditions. Compare vibration amplitude, spectrum and phase with the pre-repair record during the approved return to service. A lower overall value is encouraging, but the result is more convincing when the relevant frequency component and associated temperature or operating symptoms also return toward their established baseline.